Pull-Off Testing
Pull-off tests to prove the bond of coatings, renders, screeds and repair mortars to the concrete beneath.
Defensible strength numbers, not guesswork.
A pull-off test glues a steel dolly to the surface, cores around it and pulls it off with a calibrated rig, recording the tensile stress at failure and where the failure happened: in the coating, at the bond line or in the concrete. It is the standard way to prove that a repair, a waterproofing layer or a bonded screed is holding. We report each test with its position, the failure mode and a photograph, so a result below specification is a fact you can act on rather than an argument.

Where it helps
- When a coating, screed, render or repair bond needs testing
- When near-surface tensile performance is specified for investigation
What you receive
- Test locations and preparation method
- Applied load and calculated tensile stress for each test
- Failure location and mode, with photographs
- Comparison with the supplied acceptance criterion where specified
- Corvus report and DXF/DWG test-location plan
A note on interpretation. Interpret the result with the failure mode. Failure can occur at an interface or within the substrate. A pull-off result does not establish the element's compressive strength or structural capacity.
Often surveyed together.
GPR Concrete Scanning
Ground penetrating radar scanning that finds rebar, post-tension cables, conduits and voids hidden inside concrete, before they become a problem.
Learn moreFerro Scanning
Electromagnetic scanning to map reinforcement, measure cover depth, and estimate bar diameter without touching the concrete.
Learn moreMore from Concrete Testing.
- Concrete TestingPull-Out Testing
Pull-out testing for in-situ concrete strength to BS EN 12504-3.
- Concrete TestingRebound Hammer Testing
Schmidt hammer testing for surface hardness and strength estimation.
- Concrete TestingCore Sampling
Core extraction for laboratory compressive strength testing in a UKAS facility.
Need defensible strength results?
Send the system, test specification and acceptance criteria. We call back the same working day.