Skip to main content
Corvus
Corvus surveyor scanning a stairwell wall through a grid sheet
REINFORCEMENT SURVEY

Bar Diameter Estimation

Estimate bar diameter without coring, useful when drawings are missing or out of date.

CSCS Registered Same-day call-back Marks before we leave Canary Wharf, UK-wide
What it is

Measure the cover before the fixing goes in.

Without drawings, ferro scanning is the fastest non-destructive route to a bar-diameter estimate. We use the calibrated diameter feature on professional equipment and cross-check with coring on a representative sample where required.

Hilti PS 300 Ferroscan screen showing the bar layout in a roof slab
Ferroscan on the PS 300, bar layout in a roof slab

Where it helps

  • Where an engineer needs bar-size estimates in accessible reinforcement
  • When drawings are missing or require checking

What you receive

  • Estimated bar-diameter table linked to survey positions
  • Cover readings and assumptions relevant to each estimate
  • Unresolved or unsuitable readings identified
  • Findings marked, signed site record and photographs before we leave
  • Report and DXF/DWG within 5 working days

A note on interpretation. Bar diameter is estimated where conditions allow. Dense reinforcement, depth and geometry can limit the estimate. The report identifies where it could not be resolved.

Need cover depths you can trust?

Send the element drawings and the bar-size question. We call back the same working day.

Call 020 3886 3660 Get a Quote