Skip to main content
Corvus
Corvus surveyor scanning a stairwell wall through a grid sheet
REINFORCEMENT SURVEY

Cover Depth

Concrete cover depth measurement to design and code requirements with a calibrated Ferroscan cover meter.

CSCS Registered Same-day call-back Marks before we leave Canary Wharf, UK-wide
What it is

Measure the cover before the fixing goes in.

Cover depth controls the durability of every reinforced element. We measure cover to BS EN standards, log statistics across the element, and flag bars that fall short of design or code.

Hilti PS 300 Ferroscan screen showing the bar layout in a roof slab
Ferroscan on the PS 300, bar layout in a roof slab

Where it helps

  • When cover depth needs checking against a supplied requirement
  • For reinforcement-cover evidence in a durability investigation

What you receive

  • Cover readings referenced to the surveyed areas
  • Cover-depth plan and summary statistics for those areas
  • Comparison with the supplied cover requirement where specified
  • Findings marked, signed site record and photographs before we leave
  • Report and DXF/DWG within 5 working days

A note on interpretation. The findings describe the measured areas and survey conditions. A comparison with the supplied requirement supports the engineer's assessment; it is not a blanket statement of whole-element compliance.

Need cover depths you can trust?

Send the areas and the cover requirement you need checked. We call back the same working day.

Call 020 3886 3660 Get a Quote