Cover Depth
Concrete cover depth measurement to design and code requirements with a calibrated Ferroscan cover meter.
Measure the cover before the fixing goes in.
Cover depth controls the durability of every reinforced element. We measure cover to BS EN standards, log statistics across the element, and flag bars that fall short of design or code.

Where it helps
- When cover depth needs checking against a supplied requirement
- For reinforcement-cover evidence in a durability investigation
What you receive
- Cover readings referenced to the surveyed areas
- Cover-depth plan and summary statistics for those areas
- Comparison with the supplied cover requirement where specified
- Findings marked, signed site record and photographs before we leave
- Report and DXF/DWG within 5 working days
A note on interpretation. The findings describe the measured areas and survey conditions. A comparison with the supplied requirement supports the engineer's assessment; it is not a blanket statement of whole-element compliance.
Often surveyed together.
GPR Concrete Scanning
Ground penetrating radar scanning that finds rebar, post-tension cables, conduits and voids hidden inside concrete, before they become a problem.
Learn moreConcrete Testing
Concrete strength and durability testing: rebound hammer, pull-out and pull-off tests, core extraction with laboratory compressive strength results, carbonation, chloride and half-cell potential surveys.
Learn moreMore from Ferro Scanning.
- Ferro ScanningBar Diameter Estimation
Estimate bar diameter without coring, useful when drawings are missing or out of date.
- Ferro ScanningRebar Spacing
Verify reinforcement spacing across slabs and walls for design conformance.
- Ferro ScanningReinforcement Mapping
Map reinforcement layout across walls, slabs, and beams.
Need cover depths you can trust?
Send the areas and the cover requirement you need checked. We call back the same working day.